Wisconsin · answered by Verika · verified against sources

What is the maximum slump allowed for structural concrete?

"Use a 1-inch to 4-inch slump for concrete used in structures or placed in forms, except as follows: - Do not exceed a slump of 2 inches for grade E concrete. - Increase slump as specified in 502.3.5.3 for concrete placed underwater. - The contractor may increase the slump to a maximum of 9 inches for a mixture that contains a high range water reducer conforming to 501.2.5.3.3. Do not exceed the maximum w/cm allowed for the grade of concrete being used when a high range water reducer is in use." [1] "The contractor may increase the slump to a maximum of 9 inches for a mixture that contains a high range water reducer conforming to 501.2.5.3.3. Do not exceed the maximum w/cm allowed for the grade of concrete being used when a high range water reducer is in use." [1]

Every answer carries its source — tap a citation to read the official document.

This answer came from Verika — an expert in your pocket. Ask anything, out loud or typed; answers come from your region’s regulations and your team’s own knowledge, cited to the source. If it isn’t in the sources, Verika says so.

Verika provides information with citations to help you find and understand the rules that apply to your work. It is not a substitute for professional engineering or legal judgment. Answer generated 2026-08-28; always confirm against the cited source for your project.

More Wisconsin answers